Volvo MD22L Owner's Manual Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
26
Inhibiting
An authorized dealer should test and inspect the
engine and equipment before inhibiting the engine for
a long period. It is advisible to test the compression to
find out the condition of the engine. If anything is not in
good condition let the shop repair it now while the boat
is not used.
Carried out with the boat in water
Change the fuel filter. Pump fuel and vent the system.
See “Venting the fuel system”. Check the fuel hoses
as well as the complete fuel system for leakages. If
an extra fuel filter is fitted, this filter cartridge must
also be changed.
Start the engine after venting and allow it to run at
high idle until warm. Stop the engine.
Pump out all oil from the engine and reverse gear.
Use an oil suction pump or electric type pump de-
signed for this job.
Change the oil filter.* If the engine is fitted with an
S-drive this should be drained when the boat is laid
up. Fill up the engine and reverse gear to the correct
level with Volvo Penta diesel engine oil*, which also
has corrosion protective properties. Start the engine
and check for leaks. The engine is now ready to run
on this oil next season.
* NOTE! For long-time inhibiting, exceeding normal
of-season laying-up, preservative oil must be used. In
this case the oil filter shall not be replaced until
launching.